Fuses vs PTCs(I)
This section provides guidance in choosing the best overcurrent circuit protection device...PTC or fuse...for the application. 

Many times choosing between using a Fuse or PTC is a matter of preference, though there are important considerations and common areas of applications where the use of one may be better than the other. 

For example, much of the design work for PCs, peripherals, and portable devices (smart phones, tablets, etc.) urges the use of PTCs because they are self-resettable; using a fuse that must be replaced each time an overcurrent condition occurs is unacceptable. 

In other cases, fuses may be more acceptable because they completely stop current in fault condition; this may be more desired if safety or avoidance of downstream circuit equipment is a premium concern. Fuses are also helpful for diagnostic purposes, aiding equipment designers and users in tracing the origin of the overcurrent faults.


Overcurrent Circuit Protection

The circuit designer has a choice of technologies when faced with the task of providing overcurrent protection. The traditional fuse and the Polymer based PTC (positive temperature coefficient) device represent the most common solutions employed. Understanding the differences between these two components simplifies choosing the best protection device for the application.

Fuses have been referred to as “one time” devices, in that the fuse will provide protection from the overload by opening only once and then it needs to be replaced. The heart of a typical fuse is a length of wire which is heated to its melting point by the excessive current. The circuit current flow decreases to zero as the wire melts open.

The PTC also reacts to the excessive current but is known as a “resettable” device. The polymer based unit can provide overcurrent circuit protection a number of times when reset by removing the overload. The conductive polymer increases in resistance when heated by the overload and limits the circuit current.


PTC Protection Function

The principles of operation for a fuse have been documented over the years and are generally well understood. The actual process by which the PTC provides overcurrent circuit protection is less clear and merits further discussion. So far the PTC has been identified as being polymer based, current limiting, and resettable.

The PTCs under discussion are conductive polymer based products. The polymer material used contains particles of carbon black as the conductive media. The resistance is controlled by the amount of carbon black introduced into the mixture. Heat produces some expansion of the polymer which causes the carbon black to shift resulting in less conductivity or an increase in resistance.

The PTC functions by current limiting a potentially damaging overcurrent to a safe level. Specifically the excessive current through the device causes internal heating (I2R) which raises the temperature of the PTC and results in an increase in its resistance. The resistance of the PTC is generally a small part of the total circuit impedance until the heating takes place. The increase in resistance for a polymer based PTC is nonlinear as shown in the graph below and this relatively large increase in resistance will reduce or limit the circuit current to a safe level. The transition from low to high resistance is referred to as the trip point.

The heat generated by this limited current through the higher resistance value will maintain the temperature of the PTC at a level that will cause the resistance to remain high. This thermal equilibrium condition will continue until power is removed from the circuit which allows the PTC to cool down and the resistance will decrease. The resettable feature of the PTC is based on the fact that the increase in resistance resulting from the increase in temperature is reversible. The PTC is reset or returned to the lower resistance state by removing the power from the circuit which allows the device to cool down. The unit is then ready to react to future overloads. The resistance will remain low if the cause of the overcurrent has been corrected, but if the overcurrent recurs the device will again switch to the high resistance state.
?
主站蜘蛛池模板: 久久久综合色| 中文欧美日韩| 日韩最新av| 亚洲大尺度视频| 一级黄色免费| 黄色在线视频网站| 国产又色又爽又刺激在线观看| 午夜视频网站| 91性高潮久久久久久久| 吃女人奶子| 香蕉视频链接| 全黄一级播放| 亚洲天堂伊人| 韩国黄色片网站| 91超碰免费| 自拍偷拍亚洲欧美| 欧美簧片在线| 老头吃奶性行交| 绿色小导航ˇ福利合集| 婷婷av一区二区三区| 国产欧美高清| 男女在线观看| 国产探花在线观看| 国产videos麻豆丝袜老师| 耳光调教vk| 骚虎高清| 白嫩情侣偷拍呻吟刺激| 在线观看成年人视频| 午夜操一操| 亚洲网址在线| 久久久久久久久久久久电影| 激情网站视频| 亚洲人成高清| 性做爰免费视频观看| 97超碰人| av综合色| 老司机黄色片| 羞羞歪歪漫画| 日韩av有码在线| 亚洲色图偷拍视频| 免费在线观看日韩| 日韩美女啪啪| 免费成人黄色| 亚欧视频在线播放| 国产在线喷水| 精品理论片| 91国内在线| 少女国产免费观看| 一级坐爱片| www.777色| 亚洲第一色区| 秋霞影院午夜伦| 天天摸天天做天天爽| 久久免费视频1| 黄色日本网站| 三上悠亚av网站| 淑女的欲望在线观看| 一级特黄曰皮片视频| 精品影视| www.av资源| 少妇无内裤下蹲露大唇视频| 欧美成人激情在线| 国产黄a三级三级看三级| 啊日出水了用力公子小说| 性free印度女人hd| 桃色av| 亚洲天堂男| 欧美大片在线播放| 国产成人亚洲综合| 福利av在线| 国产又粗又猛又爽免费视频| 91蜜桃色| 日本aⅴ视频| 日韩精品片| 天堂最新资源在线| 三区不卡| av电影在线观看不卡| 免费一区二区视频| 日韩伦理电影中文字幕| 日韩午夜电影在线观看| 女生张腿男生桶| 91综合视频| 第一区免费在线观看| 国产精品av在线播放| 免费裸体| 欧美大片视频| 国产小视频91| 影音资源av| 国产一区二三区| 精品国产乱码久久久久久老虎| 40到50岁中老年妇女毛片| 高清成人| 一区二区三区天堂| 男人操女人视频在线观看| 深夜老司机| 亚洲欧美日韩综合一区二区| av撸啊撸| 少妇脚交调教玩男人的视频| 干少妇18p|